The ECB50 is offered in three different models based on your required socket and voltage configurations. It is a microporocessor-driven tracer that allows three types of troubleshooting – circuit breaker identification, wire tracing in walls, and wire sorting.
The transmitter module generates a coded signal that is injected into a powered AC line. The receiver wand uses this encoded signal to reject noise and correctly identify the right circuit breaker wire.
ECB50 is rated CAT III 150V and has a standard NEMA 5-15 plug that is common to the United States and Canada.
ECB50-E is rated CAT III 300V and uses a BS1363 3-wire standard plug for British power outlets.
ECB50-FGIS is rated CAT III 300V and uses a standard Shuko CEE 7/4 plug.
|
Specifications
|
| Transmitter |
| Voltage range: |
100 V to 125 V ECB50, 100 V to 250 V for ECB50-E and ECB50-FGIS |
| Power consumption: |
Approximately 1 W |
| Frequency range: |
30 to 70 Hz ECB50, 50 to 60 Hz for ECB50-E and ECB50-FGIS |
| Transmission frequency: |
Approximately 8 kHz |
| Transmitter frequency: |
Approximately 10 Hz |
|
| Receiver |
| Tracing depth for fuse identification: |
Approximately 0 to 10 cm (4 in) depending on local conditions. |
| Tracing depth for cable location: |
Approximately 0 to 40 cm (15 in) depending on local conditions. |
|
|
Transmitter General Specifications
|
| Operating temperature range: |
|
-10 °C to 40 °C (14 ° to 104 °F) at max 80 % R.H. |
|
| Dimensions: |
|
70 x 55 x 86 mm (2.8 x 2.1 x 3.4 in) |
|
| Weight: |
|
Approximately 65 g (2.3 oz) |
|
| Overvoltage category: |
|
CAT III 150 V ECB 50 |
|
CAT III 300 V ECB50-E and ECB50-FGIS |
|
| Pollution degree |
|
2, Protection Class: IP20 |
|
|
Receiver General Specifications
|
| Sensitivity setting |
|
| Low battery indication |
|
| Switching fuse/cable |
|
Manually using Fuse-Line switch |
|
| Operating temperature range |
|
-10 °C to 40 °C (14 ° to 104 °F) at max 80 % R.H. |
|
| Dimensions: |
|
22 x 162 x 34 mm ( 0.9 x 6.4 x 1.3 in) |
|
| Weight: |
|
Approximately 100 g (3.5 oz) |
|
| Overvoltage category |
|
CAT III 150 V ECB 50 |
|
CAT III 300 V ECB50-E and ECB50-FGIS |
|
| Pollution degree |
|
2, Protection Class: IP20 |
|
| Power supply |
|
9 V battery, IEC 6LR61, Alkaline only |
|
| Applicable directives |
|
EMC: EN 50081-1 and EN 50082-1 and standards |
|
Trade Price : £50.00